Moxa Technologies MGate 4101-MB-PBS User Manual

Browse online or download User Manual for Gateways/controllers Moxa Technologies MGate 4101-MB-PBS. Moxa Technologies MGate 4101-MB-PBS User`s manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Slave Gateway User’s Manual

MGate-4101-MB-PBS Modbus Serial-to-PROFIBUS Slave Gateway User’s Manual First Edition, October 2011 www.moxa.com/product © 2011 Moxa Inc. All rights

Page 2

MGate 4101-MB-PBS UM Hardware 3-3 Orange Steady: Error in Configuration. Blinking: Error in Parameter data Off PROFIBUS offline or Slave ID wrong.

Page 3 - Table of Contents

MGate 4101-MB-PBS UM Hardware 3-4 6 5V 7 N.C. 8 PROFIBUS D- 9 N.C. Console (RS-232) Pin Assignment The MGate 4101-MB-PBS series use RJ45 serial

Page 4 - Introduction

MGate 4101-MB-PBS UM Hardware 3-5 Specifications Power Input Input Voltage 12 to 48 VDC Connector 8-pin terminal block (GND, V1+, V1-, R

Page 5 - Product Features

MGate 4101-MB-PBS UM Hardware 3-6 Warranty 5 years Adjustable Pull High/Low Resistors for the Modbus Port (P1) in RS-485 Mode SW 1 2 3

Page 6 - Getting Started

MGate 4101-MB-PBS UM Hardware 3-7 To reset the MGate to the factory default settings, hold down the reset button for about 5 seconds. The MGate will

Page 7 - Connecting PROFIBUS Devices

4 4. Configuration The following topics are covered in this chapter:  Installing the Software  Starting MGate Manager  Connecting to the Unit

Page 8 - Hardware

MGate 4101-MB-PBS UM Configuration 4-2 Installing the Software The following instructions explain how to install MGate Manager, a utility for config

Page 9 - LED Indicators

MGate 4101-MB-PBS UM Configuration 4-3 3. When the Select Destination Location window appears, click Next to continue. You may change the destinati

Page 10 - Pin Assignments

MGate 4101-MB-PBS UM Configuration 4-4 5. Click Next to start copying the software files. 6. A progress bar will appear. The procedure should tak

Page 11 - Mounting the Unit

MGate 4101-MB-PBS UM Configuration 4-5 7. A message will indicate that MGate Manager is successfully installed. You may choose to run it immediatel

Page 12 - Specifications

MGate-4101-MB-PBS Modbus Serial-to-PROFIBUS Slave Gateway User’s Manual The software described in this manual is furnished under a license agreement a

Page 13 - Reset Button

MGate 4101-MB-PBS UM Configuration 4-6 Starting MGate Manager MGate Manager is a Windows-based utility that is used to configure the MGate 4101-MB-P

Page 14 - Rotary Switch

MGate 4101-MB-PBS UM Configuration 4-7 When you click OK, MGate Manager will immediately reflect your chosen language. After changing to a differen

Page 15 - Configuration

MGate 4101-MB-PBS UM Configuration 4-8 Specify by IP Address Specify by IP Address is used for MGate Ethernet Gateways, such as the MGate MB3000 and

Page 16 - Installing the Software

MGate 4101-MB-PBS UM Configuration 4-9

Page 17

MGate 4101-MB-PBS UM Configuration 4-10 Modifying the Configuration Once your unit is displayed in MGate Manager, select it by clicking on it. The C

Page 18

MGate 4101-MB-PBS UM Configuration 4-11 Configure Device In first page, you can change device name and select a Password to protect the unit from un

Page 19

MGate 4101-MB-PBS UM Configuration 4-12 Configure Modbus Settings The Serial tab is where Modbus serial port’s communication parameters are configur

Page 20 - Starting MGate Manager

MGate 4101-MB-PBS UM Configuration 4-13 Max. Retry Master mode only, the number of times the master will retry the same request when response time

Page 21 - Connecting to the Unit

MGate 4101-MB-PBS UM Configuration 4-14 IO Mapping Setup In this page, you should define all commands that Modbus uses and all I/O modules PROFIBUS

Page 22 - Connect through COM Port

MGate 4101-MB-PBS UM Configuration 4-15 Each Modbus request includes Enable, Modbus slave ID, Function Code, Address, Length, Internal Address, Poll

Page 23

Table of Contents 1. Introduction ...

Page 24 - Modifying the Configuration

MGate 4101-MB-PBS UM Configuration 4-16 After all Modbus requests finish, all the data collected from Modbus should be mapped to PROFIBUS I/O module

Page 25 - Configure Device

MGate 4101-MB-PBS UM Configuration 4-17 NOTE Each “ID” of the commands must be mapped, that is, the commands in Modbus will correspond with the I/O

Page 26 - Configure Modbus Settings

MGate 4101-MB-PBS UM Configuration 4-18 The interface of next dialog is divided into two sections. The upper section is labeled Modbus and will dis

Page 27 - Set up PROFIBUS

MGate 4101-MB-PBS UM Configuration 4-19 IO Map The IO Map is a mechanism which is applied when data from different networks are exchanged via the ga

Page 28 - IO Mapping Setup

MGate 4101-MB-PBS UM Configuration 4-20 In addition you can select the Paging checkbox to enable the page function, so the utility will insert two

Page 29

MGate 4101-MB-PBS UM Configuration 4-21 The IO map interface shows input and output memory array. The row unit is internal address and the column un

Page 30

MGate 4101-MB-PBS UM Configuration 4-22 Load Default If for some reason you would like to clear all the settings of the unit, the load default butto

Page 31 - QuickLink

MGate 4101-MB-PBS UM Configuration 4-23 Monitoring Modbus Activity For troubleshooting or management purposes, you can monitor the data passing thro

Page 32

MGate 4101-MB-PBS UM Configuration 4-24 Open Traffic Monitor Window Select the unit that you wish to monitor and click Monitor to open the Traffic

Page 33

MGate 4101-MB-PBS UM Configuration 4-25 To stop capturing the log, press the Stop button. Save Log to File To save the data log to a file, click

Page 34

1 1. Introduction Welcome to the MGate 4101-MB-PBS line of Modbus to PROFIBUS gateways. All models feature easy protocol conversion from Modbus to P

Page 35

MGate 4101-MB-PBS UM Configuration 4-26 Diagnose Diagnose is a powerful function to identify communications problems and assist in troubleshooting w

Page 36 - Load Default

MGate 4101-MB-PBS UM Configuration 4-27 There are two parts. In Modbus tab, the first part is the information regarding Modbus. These details will h

Page 37 - Monitoring Modbus Activity

MGate 4101-MB-PBS UM Configuration 4-28 Output The output bytes Input The input bytes Illegal I/O Config The number of illegal I/O configs Restar

Page 38

MGate 4101-MB-PBS UM Configuration 4-29 Once the firmware has been successfully written onto the unit, click Exit to close the Upgrade Firmware win

Page 39 - Save Log to File

MGate 4101-MB-PBS UM Configuration 4-30 If you export the configuration file successfully, a confirmation message will pop up. After that, the con

Page 40 - Diagnose

MGate 4101-MB-PBS UM Configuration 4-31 Please be patient and wait as MGate Manager configures the target device. If you import the configuration

Page 41

A A. Quick Configuration The following topics are covered in this appendix:  Typical Applications  Quick Configuration Steps  PROFIBUS Overv

Page 42 - Upgrading Firmware

MGate 4101-MB-PBS UM Quick Configuration A-2 Typical Applications Here is a typical application to demonstrate how to use the Quick Link function an

Page 43 - Import/Export

MGate 4101-MB-PBS UM Quick Configuration A-3 Quick Configuration Steps MGate 4101-MB-PBS provides an innovative function which can automatically a

Page 44

MGate 4101-MB-PBS UM Quick Configuration A-4 Modbus Overview Introduction Modbus is one of the most popular automation protocols in the world. It s

Page 45

MGate 4101-MB-PBS UM Introduction 1-2 Overview The MGate 4101-MB-PBS is a line of protocol gateways that provides users with the following features:

Page 46 - Quick Configuration

MGate 4101-MB-PBS UM Quick Configuration A-5 Exception The master sends a request to the slave. The slave may not support the command or an error

Page 47 - Typical Applications

MGate 4101-MB-PBS UM Quick Configuration A-6 Integrate Modbus Serial and Ethernet with Gateways 7 Ordinarily, Modbus TCP and Modbus ASCII/RTU are un

Page 48 - PROFIBUS Overview

2 2. Getting Started The following topics are covered in this chapter:  Connecting Power  Connecting PROFIBUS Devices  Connecting Modbus Seria

Page 49 - Modbus Overview

MGate 4101-MB-PBS UM Getting Started 2-2 Connecting Power The unit can be powered using the AC adaptor or by connecting a power source to the termin

Page 50 - Response Timeout

3 3. Hardware The following topics are covered in this chapter:  Function Block  Power Input and Relay Output Pinouts  LED Indicators  Dimen

Page 51 - Diagnose Packet Format

MGate 4101-MB-PBS UM Hardware 3-2 Function Block Power Input and Relay Output Pinouts V2+ V2- V1+ V1- Shielded Ground DC Power Input 2 DC