Moxa Technologies EDS-405A User Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 112
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
EDS-405A/408A Series User’s Manual Featured Functions
3-3
Password
Setting Description Factory Default
Old Password (Max.
16 Characters)
Type current password when changing the
password
None
New Password (Max.
16 Characters)
Type new password when changing the
password
None
Retype Password
(Max. 16 Characters)
If you type a new password in the
Password field, you will be required to
retype the password in the Retype new
password field before updating the new
password.
None
Accessible IP
An IP address-based filtering method to control access to EDS switches.
Accessible IP Settings allows you to add or remove Legal remote host IP addresses to prevent
unauthorized access. Access to the EDS is controlled by IP addresses. That is, if a host’s IP address
is in the accessible IP table, then the host will be allowed access to the EDS. You can allow one of
the following cases by setting this parameter
y Only one host with the specified IP address can access the EDS-405A/408A
E.g., enter “192.168.1.1/255.255.255.255” to allow access to just the IP address 192.168.1.1.
y Any host on a specific sub network can access the EDS-405A/408A
E.g., enter “192.168.1.0/255.255.255.0” to allow access to all IPs on the sub network defined
by this IP address/netmask combination.
y Any host can access the EDS-405A/408A
Disable this function by not selecting the Enable the accessible IP list checkbox.
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 111 112

Comments to this Manuals

No comments