V460 Series WinCE User’s Manual Second Edition, May 2008 www.moxa.com/product © 2008 Moxa Inc., all rights reserved. Reproduction without permission

Page 2

V460 Series WinCE User’s Manual Introduction 1-6Storage Temperature -20 to 80°C (-4 to 176°F), 5 to 95% RH -40 to 85°C (-40 to 185°F) is optional fo

Page 3 - Table of Contents

V460 Series WinCE User’s Manual Introduction 1-7Networking and Communications Capabilities For network-centric embedded application usage, the V460

Page 4

V460 Series WinCE User’s Manual Introduction 1-8y Audio Codecs and Renderers G.711 Audio Codec GSM 6.10 Audio Codec IMA ADPCM Audio Codec MP3 Codec

Page 5 - Introduction

V460 Series WinCE User’s Manual Introduction 1-9Since embedded computers have resource limits, integrators must store data wisely. In general, you s

Page 6 - Package Checklist

V460 Series WinCE User’s Manual Introduction 1-10RS-232/422/485 Serial Ports The V460’s serial ports are numbered from left to right and bottom usin

Page 7 - Product Features

22 Chapter 2 Getting Started In this chapter, we explain how to operate a V460 computer from a PC. For clarity, the PC will be referred to as a “d

Page 8

V460 Series WinCE User’s Manual Getting Start 2-2Starting your V460 Computer Connect the CRT monitor or LCD monitor to the target computer, and then

Page 9

V460 Series WinCE User’s Manual Getting Start 2-3Step1: Scan Disk (Automatically) The system will scan the disk automatically when you start the res

Page 10 - Product Software Features

V460 Series WinCE User’s Manual Getting Start 2-42. Right-Click the LAN interface that you would like to configure and then click [property]. A con

Page 11

V460 Series WinCE User’s Manual Getting Start 2-5 Ethernet Adapter [PCI\RTL81392]: IP Address: 192.168.4.127 SubNet Mask: 255.255.255.0 Operati

Page 12 - Memory and File Systems

V460 Series WinCE User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with

Page 13 - Inserting a USB Mass Storage

V460 Series WinCE User’s Manual Getting Start 2-6 Adding a User: Use the command useradd <newUserID> to add a user for accessing the system. T

Page 14 - Digital IO (V468 Only)

V460 Series WinCE User’s Manual Getting Start 2-7Start the FTP service by typing \> services start FTP0: Stop the FTP service by typing \> ser

Page 15 - Getting Started

V460 Series WinCE User’s Manual Getting Start 2-8\> ping www.Moxa.com Pinging Host www.Moxa.com [192.168.1.16] Reply from 192.168.1.16: Echo size

Page 16 - Resetting Your V460 Computer

33 Chapter 3 Management Tools The V460 of ready-to-run embedded computers are network-centric platforms designed to serve as front-end computers f

Page 17

V460 Series WinCE User’s Manual Management Tools 3-2 System Information The first page displays the system information of the V460 computer, includin

Page 18

V460 Series WinCE User’s Manual Management Tools 3-3 Process (Thread) Monitoring/Control At runtime, the V460 computer manages up to 32k applications

Page 19 - User/Group Management

V460 Series WinCE User’s Manual Management Tools 3-4 You can also adjust the time automatically by using SNTP. Click on the check box to enable the s

Page 20 - Adjusting Time Zone

V460 Series WinCE User’s Manual Management Tools 3-5 Display The V460 VGA output works through a CRT connector to display the Windows CE desktop on a

Page 21

V460 Series WinCE User’s Manual Management Tools 3-6

Page 22

V460 Series WinCE User’s Manual Management Tools 3-7 Auto Launch Configuration You can specify programs to execute automatically after booting up. Cl

Page 23 - Management Tools

Table of Contents Chapter 1 Introduction...1-1 Overv

Page 24 - Serial Port Configuration

V460 Series WinCE User’s Manual Management Tools 3-8 On this administration page, you can create a new web site or create a virtual web path for you

Page 25 - Services Monitoring/Control

44 Chapter 4 System Recovery The V460 series of ready-to-run embedded computers are Windows CE 6.0 OS platforms, and the internal file systems sup

Page 26 - Automatic Launch

V460 Series WinCE User’s Manual System Recovery 4-2Recovery Environment The environment includes the hardware and recovery programs for conducting p

Page 27 - Display

V460 Series WinCE User’s Manual System Recovery 4-3 2. Bios setup on the V460. a. Insert the USB disk into the V460 computer. b. Power on and pre

Page 28

V460 Series WinCE User’s Manual System Recovery 4-4

Page 29 - Web Server Configuration

V460 Series WinCE User’s Manual System Recovery 4-53. System recovery a. If the bios setup is correct, the computer will restart and boot from the

Page 30

AA Appendix A Firmware Upgrade Procedure To upgrade the V460 firmware, you must download the firmware upgrade installation file. This firmware ins

Page 31 - System Recovery

V460 Series WinCE User’s Manual Firmware Upgrade Procedure A-2 6. Please allow at least one minute to complete the upgrade process. After the firm

Page 32 - Recovery Procedures

Recovery Programs... 4-2 Recovery Pro

Page 33

11 Chapter 1 Introduction Microsoft® Windows® CE 6.0 is an open, scalable, 32-bit operating system (OS) that allows you to build a wide range of i

Page 34

V460 Series WinCE User’s Manual Introduction 1-2Overview The V460 series of x86 ready-to-run embedded computers is designed around the AMD LX800 and

Page 35

V460 Series WinCE User’s Manual Introduction 1-3All models of the V462/464/466/468 series are shipped with the following items: y 1 V460 Series Emb

Page 36 - Firmware Upgrade Procedure

V460 Series WinCE User’s Manual Introduction 1-4Product Hardware Specifications System CPU AMD Geode LX [email protected] processor with 128K L2 Cache, 500 M

Page 37

V460 Series WinCE User’s Manual Introduction 1-5Digital Input (V468 only) Input Channels 8, source type Digital input levels Dry contact: Logic le