CN2510 User’s Manual Troubleshooting
A-5
How to Save CN2510’s Parameters
Question: How can I save CN2510’s parameters to recover from unexpected power failures,
or to transfer the same parameters to another CN2510?
Solutions:
¾ After entering the Console screen, select seTting Æ Export, and press Enter. Then you
can use XMODEM for a Windows host, or RCP for a UNIX host, to save the parameters
to a file.
CN2510-8 CN2510-8_5631 V2.0 MAIN MENU
------------------------------------------------------------------------------
Server Port [seTting] sAve Utility Restart Exit
Export or import configuration
Enter: select ESC: previous menu
CN2510-8 CN2510-8_5631 V2.0 SETTING MENU
------------------------------------------------------------------------------
[Export] Import Default Quit
Export current configuration to file
Enter: select ESC: previous menu
CN2510-8 CN2510-8_5631 V2.0
------------------------------------------------------------------------------
[Export] Import Default Quit
Export current configuration to file
ESC: back to menu Enter: select
Export via [Console port (using XMODEM)]
Host name/IP address [ ]
File name [ ]
User name [ ]
Press CTRL-U to start ...
ASPP Port Problems
Problem: The application utilizing the ASPP subroutines could not connect to the CN2510.
Solutions:
¾ Check to see if the target port’s mode is set to ASPP. The connection will fail if the port
mode is set to something other than ASPP. After entering the Console screen, select Port
Æ Mode, move the cursor to the Application corresponding to the serial port, and set it to
Device Control. In the Mode column, select ASPP.
¾ Moxa provides example programs on the website (
www.moxa.com) that can be
downloaded.
Comments to this Manuals