PCI Express Board User's Manual Driver Installation: Windows XP/2003
data interactively, send patterns periodically, and transfer files using ASCII, XMODEM, YMODEM, ZMODEM,
and KERMIT protocols.
To run Terminal Emulator, click Start
Program PComm Lite Terminal Emulator.
RS-485 Programming
If you are using your CP-118EL Series board for RS-485 applications, in addition to reading this section, you
should also refer to the “Connection Cables and Cable Wiring” chapter for more details about using RS-485.
The CP-118EL Series supports 2-wire half-duplex RS-485 and 4-wire full duplex RS-485 communication. Ports
configured for 2-wire RS-485 use the Data+ and Data- pins for both transmitting and receiving data. Moxa’s
own ADDC™ (Automatic Data Direction Control) technology is used to switch between transmission and
reception.
ADDC™
ADDC™ is the best method for switching between transmission and reception when using 2-wire RS-485.
When using ADDC™, additional code is not required to switch between data transmission and reception, since
the board’s built-in intelligent hardware mechanism automatically manages the switching mechanism. RS-485
programming using ADDC™ mode is just as simple and straightforward as RS-232 or RS-422 programming.