CN2510 User’s Manual Troubleshooting
A-2
Console Terminal Problems
Problem: No message is displayed on the console terminal.
Solutions:
¾ Check to see if the terminal is set to 115200 bps, 8 data bits, no parity, 1 stop bit.
¾ Check to see if the RS-232 cable is wired correctly. The console needs CTS/DCD signals
to trigger. Refer to the “Cable Wiring” section in Appendix D.
¾ The console may be blocked waiting for an event. Press ESC to try unblocking.
Problem: Garbage characters are displayed on the console terminal.
Solutions:
¾ Check to see if the terminal is set to 115200 bps, 8 data bits, no parity, 1 stop bit.
¾ Check to see if terminal type setting is correct. The console only accepts ansi/vt100 or
vt52.
¾ Press Ctrl-L to refresh the display.
Question: How can I restore CN2510 to the factory default settings?
Solution:
¾ After entering the Console window, select setting Æ Default, and then press Enter. The
CN2510 will be restored to the factory default settings.
CN2510-8 CN2510-8_5631 V2.0 MAIN MENU
---------------------------------------------------------------------------
Server Port [seTting] sAve Utility Restart Exit
Export or import configuration
Enter: select ESC: previous menu
CN2510-8 CN2510-8_5631 V2.0
---------------------------------------------------------------------------
Export Import [Default] Quit
Load the factory setting
ESC: back to menu Enter: select
+--------------------------------------------------+
|Enter to load factory setting, other key to cancel|
+--------------------------------------------------+