EDS-508 Series User’s Manual Featured Functions
3-6
Port Transmission Speed
Setting Descriptions Factory Default
Auto-nego Allows the port to negotiate with connected
devices according to IEEE 802.3u. The port
and connected device will determine the best
match.
100M-Full
100M-Half
10M-Full
10M-Half
Choose one of these fixed speed options if the
opposing Ethernet device has trouble
auto-negotiating for line speed.
Auto-nego
Port Type
Setting Descriptions Factory Default
Auto
Allows the port to auto detect the port type of
the opposing Ethernet device and change the
port type accordingly.
MDI
MDIX
Choose the MDI or MDIX option if the
opposing Ethernet device has trouble
auto-negotiating for port type.
Auto
FDX Flow Control
This setting enables or disables the flow control capability of this port when the “port transmission
speed” setting is in “auto-nego” mode. The final result will be determined by the auto-nego
process between EDS and connected device.
Setting Descriptions Factory Default
Enable
Enables the flow control capability of this port
when in auto-nego mode.
Disable
Disables the flow control capability of this
port when in auto-nego mode.
Enable