CN2610 User’s Manual Setting Up Dial-in/Out
11-13
Configuring the Serial Ports
Open Port Menu Æ Line to configure serial port settings.
1. From the MAIN MENU, select Port, and then press Enter.
CN2610-8 CN2610-8_19 V2.0 MAIN MENU
------------------------------------------------------------------------------
Server [Port] seTting sAve Utility Restart Exit
Examine/modify async server ports configuration
Enter: select ESC: previous menu
2. From the PORT MENU, select Line, and then press Enter.
CN2610-8 CN2610-8_19 V2.0 PORT MENU
------------------------------------------------------------------------------
Mode [Line] mOdem Welcome_MSG Quit
Examine/modify asynchronous port configuration
Enter: select ESC: previous menu
3. The Line page has pop-up selection lists for Port, Speed, Bits, Stop, Parity, FIFO,
RTS/CTS, XON/XOFF, and Discon. ctrl for each serial port. Each item is described in detail
below the figure.
CN2610-8 CN2610-8_19 V2.0
------------------------------------------------------------------------------
Mode [Line] mOdem Welcome_MSG Quit
Examine/modify asynchronous port configuration
ESC: back to menu Enter: select
Port Speed Bits Stop Parity FIFO RTS/CTS XON/XOFF Discon. ctrl
01 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
02 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
03 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
04 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
05 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
06 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
07 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
08 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
Setting Value Notes
Speed 50 bps to 921.6 Kbps Transmission rate
Bits 5, 6, 7, 8 Data bits
Stop 1, 1.5, 2 Stop bits
Parity None, Even, Odd, Mark, Space Odd, Even, Mark, Space
FIFO Yes, No First In First Out Device
RTS/CTS Yes, No Hardware Flow Control
XON/XOFF Yes, No Software Flow Control
None DSR off or DCD off will not be
interpreted as a disconnection.
DSR off DSR off will be interpreted as a
disconnection.
Discon. Ctrl
DCD off DCD off will be interpreted as a
disconnection.