CN2610 User’s Manual RADIUS Server
B-6
OS Command
SCO OpenServer
#mount -f ISO9660, filemode=444 <device>
Example: #mount-f ISO9660, filemode=444 /dev/cd1/mnt
Solaris x86 In the volume manager mounts the CD-ROM on mount point
/cdrom/cdrom0
Linux #mount /dev/cdrom or
#mount-t iso9660-ro mode=0555<device>
Example: #mount-t iso9660-ro mode=0555/dev/hdb/mnt
3. Copy the file to the UNIX host.
#cp /mnt/cdrom/radius.2.3.tar
4. Extract the .tar to files.(radiu.2.3 subdirectory)
#tar xvf radius.2.3.tar
After extracting, there are subdirectories, as follows:
/src: source code
/conf: configuration
/log: log record
/temp: temporary files
/bin: execution files
5. Compile and link.
#cd /src
#sh mk_radius
RADIUS Server Configuration
+--------------------------------------------------------------------+
| MOXA RADIUS SERVER Administration |
+--------------------------------------------------------------------+
| >Configuration |
| Monitor |
| Daemon Control |
| Report |
| Others |
+--------------------------------------------------------------------+
| J:Down K:Up Q:Quit Enter:Select |
+--------------------------------------------------------------------+
1. Specify password file.
“Configuration”
Æ
“Basic Configuration”
Æ
Password File
(/etc/passwd for LINUX)
(/etc/shadow for SCO UNIX and SOLARIS)
(/etc/master.passwd fot FREEBSD and BSDI)