CN2610 User’s Manual Setting Up DRDAS
7-3
CN2610-8 CN2610-8_19 V2.0 MAIN MENU
------------------------------------------------------------------------------
Server [Port] seTting sAve Utility Restart Exit
Examine/modify async server ports configuration
Enter: select ESC: previous menu
4. From the PORT MENU, select Mode, and then press Enter.
CN2610-8 CN2610-8_19 V2.0 PORT MENU
------------------------------------------------------------------------------
[Mode] Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
Enter: select ESC: previous menu
5. In Mode, use the arrow keys to move the cursor to the application corresponding to serial
ports. Here we use Port 6 as an example.
CN2610-8 CN2610-8_19 V2.0
------------------------------------------------------------------------------
[Mode] Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
ESC: back to menu Enter: select
Port Application Mode Description/more setting
01 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
02 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
03 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
04 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
05 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
06 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
07 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
08 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
6. Press Enter to open the application window. Use up/down arrow keys to select DRDAS, and
then press Enter to confirm using DRDAS.
CN2610-8 CN2610-8_19 V2.0
------------------------------------------------------------------------------
[Mode] Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
ESC: back to menu Enter: select
Port Application +------------------+ption/more setting
01 [DRDAS ]| Disable |PC redundant data mode ]
02 [DRDAS ]| Dialin/out |PC redundant data mode ]
03 [DRDAS ]| Terminal |PC redundant data mode ]
04 [DRDAS ]| Reverse Terminal |PC redundant data mode ]
05 [DRDAS ]| Device Control |PC redundant data mode ]
06 [DRDAS ]| Multiplex |PC redundant data mode ]
07 [DRDAS ]| Printer |PC redundant data mode ]
08 [DRDAS ]| Multi-Host TTY |PC redundant data mode ]
09 [DRDAS ]| NT Real COM |PC redundant data mode ]
10 [DRDAS ]| DRDAS |PC redundant data mode ]
11 [DRDAS ]| Raw UDP |PC redundant data mode ]
12 [DRDAS ]+------------------+PC redundant data mode ]
7. Repeat Step 6 to configure port settings. For example, you can perform the following steps to
configure Port 1 to Port 8 for the DRDAS application.