CN2610 User’s Manual Knowing Your Application
3-8
Console Management (Reverse Terminal)
CN2610
TCP/IP
Telnet
Server
RS-232
Reverse Telnet
mode
Router Server
Unix
Windows NT
Rx
Tx
12345678910111213141516
Reset
Ready
SELMENU
CN2610
16 port RS-232 Async Server
The Reverse Terminal application, which uses Rtelnet mode, is used with routers, switches, and
UPS equipment for console management applications. Rtelnet mode is similar to RAW mode, in
that after booting up it listens to one specific TCP port for network hosts to initiate a connection.
RAW mode, however, does not provide a Telnet conversion function. If the serial devices
connected to CN2610 need to use the CR/LF conversion function, then Rtelnet mode must be used.
CN2610’s Rtelnet mode is also used widely for device management applications in
telecommunication control rooms, since remote hosts can make use of Local User Table or
RADIUS identity verification methods.
Refer to Chapter 8 for detailed information and configuration instructions.