CN2610 User’s Manual Setting Up Device Control
5-7
CN2610-8 CN2610-8_19 V2.0
------------------------------------------------------------------------------
[Mode] Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
ESC: back to menu Enter: select
Port Application Mode Description/more setting
01 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
02 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
03 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
04 [NT Real COM ] [ASPP ]+----------+rver Proprietary Protocol]
05 [NT Real COM ] [ASPP ]| ASPP |rver Proprietary Protocol]
06 [Device Control ] [ASPP ]| RAW |rver Proprietary Protocol]
07 [NT Real COM ] [ASPP ]+----------+rver Proprietary Protocol]
3. Move the cursor to the Description/more setting column, and then press Enter. The pop-up
selector contains input/display fields for TCP port, Source IP address, Destination IP addr,
Inactivity time, and TCP alive check time. Each item is described in detail below the figure.
CN2610-8 CN2610-8_19 V2.0
------------------------------------------------------------------------------
[Mode] Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
ESC: back to menu Enter: select
Port Application Mod+----------------------------------------+
01 [NT Real COM ] [AS| TCP port : [4001 ] |]
02 [NT Real COM ] [AS| Source IP address : [ ] |]
03 [NT Real COM ] [AS| Destination IP addr : [ ] |]
05 [NT Real COM ] [AS| Inactivity time : [0 ] minutes |]
06 [Device Control ] [RA| TCP alive check time : [0 ] minutes |]
07 [NT Real COM ] [AS+----------------------------------------+]
08 [NT Real COM ] [ASPP ] [Async Server Proprietary Protocol]
Setting Value Notes Necessity
TCP port number Each of CN2610’s serial ports is mapped to a
TCP port. You may modify these port
numbers, but to avoid conflicts among TCP
port numbers for other serial ports, we
strongly suggest using the default values:
4001 for port 1, 4002 for port 2, etc.
Optional
Source IP
address
IP address for
the port
Specify an IP address for this port for
application purposes. If left blank, CN2610
will use its own IP address, in which case you
will need to specify different TCP port
numbers for different serial ports.
Optional
Destination IP
addr
IP address The host with this IP address will have
exclusive access to this port. If left blank, all
hosts on the network will have access to this
port.
Optional
Inactivity time 0-99 minutes Idle time before the port is disconnected
automatically. If set to 0 minutes, the port will
not disconnect.
Optional
TCP alive
check time
0-99 minutes The time period CN2610 waits before
checking if the TCP connection is alive or not.
If no response is received, CN2610 will reset
the port and terminate the connection.
Optional